Main function
Safety controller
Functions
Safety controller
Atmosphere -- no corrosive gas
Design
unit version 2.0
2000m max. operating altitude
Supply voltage (DC)
20.4-26.4Vac (24Vdc nom.)
Connection type
M3 self-rising screw connection
Leakage current
0.1mA max. (test output; safety output) mA
Digital inputs
20 x safety inputs (PNP sinking; 6mA; 11Vdc min. ON voltage; 5Vdc max. OFF voltage; between each input and G1; 1mA max. OFF current)
Digital outputs
8 x safety outputs (PNP sourcing; 3.2A max. / 1.2V max. ON residual voltage; between each output and V2 / 2V max. OFF residual voltage)
6 x TEST outputs (T0/T1/T2 100mA max.; T3 300mA max.; T4/T5 30mA max.; T0-T2 and T4-T5 total 120mA max. / 1.8V max. ON residual voltage; between each output and V1)
Degree of protection
IP20
Ambient air temperature for operation
0...+55 °C
Ambient air temperature for storage
-20...+75 °C
Current consumption
500mA (V1 400mA; V2 100mA)
Technical compatibility with
G9SP series
Order code / Manufacturer SKU
G9SP-N20S
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC 61131-2 - noise immunity
Isolation class III (SELV)
Overvoltage category II
EN ISO 13849-1
EN ISO 13849-2
IEC 61508 - 1-7
EN 62061
IEC 61131-2
EN ISO 13850
EN 60204-1
EN 61000-6-2
Vibration resistance - 5 to 8.4 Hz amplitude of 3.5mm - 8.4 to 150 Hz; 9.8m/s2
Shock resistance - 147m/s2; 11ms
EN 61000-6-4
NFPA 79
ANSI RIA R15.06
ANSI B11.19
ANSI/UL 1998
UL 508
CSA22.2 No.142
KOSHA S Mark