Products >> Omron >> Inverter
Omron Inverter 3G3MX2-A4004-ZV1
- Product No.:2023101412574
Specification
High starting torque and torque control capability in open loop mode give you full control of your machine dynamics and performance. Options for all of the major open network systems.
1. Torque master
The MX2-V1 delivers 200% starting torque near stand-still (0.5 Hz) and can operate in torque control in open loop mode. This allows the MX2-V1 to be used in applications where closed loop AC vector drives were previously used.
2. Easy network integration
Standard industrial networks, such as EtherCAT, CompoNet or DeviceNet as options. High-speed EtherCAT provides solutions for the entire system from input to output with Sysmac Series.
3. Easy communications setting
Built-in RS-485 Modbus communications. OMRON Function Blocks are available for the CP H/L and CJ-series PLCs. Those control the MX2-V1 via Modbus communications easily.
High starting torque and torque control capability in open loop mode give you full control of your machine dynamics and performance. Options for all of the major open network systems.
1. Torque master
The MX2-V1 delivers 200% starting torque near stand-still (0.5 Hz) and can operate in torque control in open loop mode. This allows the MX2-V1 to be used in applications where closed loop AC vector drives were previously used.
2. Easy network integration
Standard industrial networks, such as EtherCAT, CompoNet or DeviceNet as options. High-speed EtherCAT provides solutions for the entire system from input to output with Sysmac Series.
3. Easy communications setting
Built-in RS-485 Modbus communications. OMRON Function Blocks are available for the CP H/L and CJ-series PLCs. Those control the MX2-V1 via Modbus communications easily.
Function name | Specifications |
Enclosure ratings *1 | Open type (IP20) |
Control method | Phase-to-phase sinusoidal modulation PWM |
Output frequency range *2 | 0.10 to 400 Hz (or 580 Hz in the high-frequency mode; restrictions apply) |
Frequency precision *3 | Digital command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max. frequency (25±10°C) |
Frequency setting resolution | Digital setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency |
Voltage/Frequency characteristics | V/f characteristics (constant/reduced torque)Sensorless vector control, V/f control with speed feedback |
Overload current rating | Heavy load rating (CT): 150%/60 s Light load rating (VT): 120%/60 s |
Instantaneous overcurrent protection | 200% of the value of heavy load rating (CT) |
Acceleration/Deceleration time | 0.01 to 3600 s (linear/curve selection), acceleration/deceleration 2 setting available |
Carrier frequency adjustment range | 2 to 15 kHz (with derating) |
Starting torque | 200%/0.5 Hz (sensorless vector control) |
External DC injection braking | Starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than that during operation, or via an external input. (Level and time settable). |
Protective functions | Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcur- rent at power-on status, rush current prevention circuit, overload limit, incoming overvoltage, external trip, memory error, CPU error, USP error, communication error, overvoltage suppression during deceleration, protection upon momentary power outage, emergency cutoff, etc. |
Frequency settings | Digital OperatorExternal analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus communication (Modbus-RTU) |
RUN/STOP command | Digital OperatorExternal digital input signal (3-wire input supported), Modbus communication (Modbus-RTU) |
Multi-function input *4 | 7 points (Functions can be selected from among 68) |
Analog input *5 | 2 points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10 bits/4 to 20 mA) |
Pulse input | 1 point (RP terminal: 32 kHz max., 5 to 24 VDC) |
Multi-function output *4 | 2 points (P1 and P2, Functions can be selected from among 47) |
Relay output *4 | 1 point (SPDT contact (MC, MA, MB), Functions can be selected from among 47) |
Analog output (Frequency monitor)*6 | 1 point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current selectable) |
Pulse output | 1 point (MP terminal: 32 kHz max., 0 to 10 V) |
RS-422 | RJ45 connector (for Digital Operator) |
RS-485 | Control circuit terminal block, Modbus communication (Modbus-RTU) |
USB | USB1.1, mini-B connector |
Other functions | AVR function, V/f characteristics switching, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S shape acceleration/deceleration, electronic thermal characteristics, level adjustment, restart function, torque boost function, fault monitor, soft lock function, frequency conversion display, USP function, motor 2 control function, UP/DWN, overcurrent control function, etc. |
Ambient operating temperature *7 | -10 to 50°C (However, derating is required). |
Ambient storage temperature | -20°C to 65°C |
Ambient operating humidity | 20% to 90% RH (with no condensation) |
Vibration resistance | 5.9 m/s2 (0.6G), 10 to 55 Hz |
Application environment | At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust) |
EtherCAT Communication Unit | 3G3AX-MX2-ECT |
CompoNet Communication Unit | 3G3AX-MX2-CRT-E |
DeviceNet Communication Unit | 3G3AX-MX2-DRT-E |
Products Category
Contact Us
Name: Jesscia/Chris
Tel: +86-1397409760 /18570360124
Mobile: 18570360124
E-mail: info@qianhuiautomation.com
E-mail: Chrish@qianhuiauto.com
WeChat: +86 18570360124
Whatsapp: +86 18570360124
Add: No. 206, 2nd Floor, Building 18, Changsha Future Wisdom Park, Changsha Pilot Free Trade Zone, Changsha